Direct On Line Starters

3WA Air Circuit Breaker

Direct On Line Starters

  • Motor Rating at 415V 3ph 50Hz: 0.33 – 10HP | 0.25 – 7.5kW
  • Contactors | OLRs: 3TS contactors | 3US/3UW overload Relay
  • Coil Voltage: 200 – 400V | 352 – 456V AC, 50Hz
  • Standard marking: ISI/IEC 60947-4-1
  • IP42

Automatic Star Delta

3WA Air Circuit Breaker

Automatic Star Delta Starters

  • Motor Rating at 415V 3ph 50Hz: 10 – 25 P | 7.5 – 18.5kW
  • Contactors | OLRs: 3TS contactors | 3US overload Relay
  • Coil Voltage: 200 – 400V | 352 – 456V AC, 50Hz
  • Standard marking: ISI/IEC 60947-4-1
  • IP42

Automatic Direct On

3WA Air Circuit Breaker

Automatic Direct On Line Starters

  • Motor Rating at 415V 3ph 50Hz: 7.5 – 17.5HP | 5.5 – 13kW
  • Clearly defined ratings for submersible pump set & for 3-phase Motors
  • Contactors | OLRs: 3TS contactors | 3US/3UW overload Relay
  • Coil Voltage: 200 – 400V | 260 – 457V AC, 50Hz
  • IP42
  • LED Indication: Indicating the incoming power supply availability & healthiness
  • Special Line Monitoring Relay for Agriculture Starters provide protection against Phase Loss, Phase Reversal, Phase Unbalance, Under voltage and Over Voltage. It can be set in 3 different modes (Manual, Auto & Bypass) to suit the farmer’s requirement.

RAJA + DOL FASD

3WA Air Circuit Breaker

RAJA + DOL Controllers & FASD With GSM

  • Motor Rating at 415V 3ph 50Hz: 3 – 10HP | 2.2 – 7.5kW DOL | 10 – 40HP | 7.5 – 30kW FASD
  • Contactors | OLRs: 3TS contactors | 3US overload Relay
  • Coil Voltage: 200 – 400V | 260 – 457V AC, 50Hz
  • In Built GSM Module for Communication
  • Complete protection against Line Faults: Phase Loss, Phase Reversal, Phase Unbalance, Under voltage, and Over Voltage
  • IP43

Direct-On-Line Controller

3WA Air Circuit Breaker

Direct-On-Line Controller

  • Motor Rating at 415V 3ph 50Hz: 3 – 10HP | 2.2 – 7.5kW
  • Clearly defined ratings for submersible pump set & for 3-phase Motors
  • Contactors | OLRs: 3TS contactors | 3US overload Relay
  • Coil Voltage: 200 – 400V | 260 – 457V AC, 50Hz
  • IP43
  • LED Indication: Amber LED Indicating the incoming power supply availability & healthiness
  • Green LED Motor on indication
  • AV meter for current, voltage indication
  • Special Line Monitoring Relay for Agriculture Starters provide protection against Phase Loss, Phase Reversal, Phase Unbalance, Under voltage, and Over Voltage. It can be set in 3 different modes (Manual, Auto & Bypass) to suit the farmer’s requirement.

Fully Automatic Star Delta Starter

3WA Air Circuit Breaker

Fully Automatic Star Delta Starter

  • Motor Rating at 415V 3ph 50Hz: 10 – 75HP | 7.5 – 55kW
  • Clearly defined ratings for submersible pump set & for 3-phase Motors
  • Contactors | OLRs: 3TS contactors | 3US overload Relay
  • Coil Voltage: 200 – 400V | 260 – 457V | 332 – 457V | 304 – 418V AC, 50Hz
  • IP43
  • LED Indication: Amber LED Indicating the incoming power supply availability & healthiness
  • Green LED Motor on indication
  • AV meter for current, voltage indication
  • Special Line Monitoring Relay for Agriculture Starters provide protection against Phase Loss, Phase Reversal, Phase Unbalance, Under voltage, and Over Voltage. It can be set in 3 different modes (Manual, Auto & Bypass) to suit the farmer’s requirement.
Go To Top